+44 207 515 5179

Message here

FLUKE 117C, Digital Multimeter Non-Contact Voltage Electrician Multimeter

Be the first to review this product

Features: VoltAlert™ technology for non-contact voltage detection AutoVolt automatic AC/DC voltage selection
Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True RMS for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) for hands free operation CAT III 600 V safety rated
Specifications: Maximum voltage between any terminal and earth ground: 600

Availability: In stock

Excl. Tax: £384.00 Incl. Tax: £460.80

V Surge protection: 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for
A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display:
Digital: 6, 000 counts, updates 4 per second
Bar graph: 33 segments, updates 32 per second
Operating Temperature: -10 °C to + 50 °C
Storage Temperature: -40 °C to + 60 °C
Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life: 400 hours typical, without backlight Accuracy Specifications DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5 % + 2 DC volts
Range/Resolution: 6.000 V / 0.001
V Range/Resolution: 60.00 V / 0.01
V Range/Resolution: 600.00 V / 0.1
V Accuracy: ± ([% of reading] + [counts]): 0.5 % + 2 Auto volts
Range: 600.0
V Resolution: 0.1
V Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001
V Range/Resolution: 60.00 V / 0.01
V Range/Resolution: 600.0 V / 0.1
V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range: 600
O Resolution: 1
O Accuracy: Beeper on less than 20 O, off more than 250 O; detects opens or shorts of 500 µs or longer.
Ohms Range/Resolution: 600.0 O / 0.1
O Range/Resolution: 6.000 k O / 0.001 k
O Range/Resolution: 60.00 k O / 0.01 k
O Range/Resolution: 600.0 k O / 0.1 k
O Range/Resolution: 6.000 M O / 0.001
M O Accuracy: 0.9 % + 1
Range/Resolution: 40.00 M O / 0.01
M O Accuracy: 5 % + 2
Diode Test Range/Resolution: 2.000 V / 0.001
V Accuracy: 0.9 % + 2
Capacitance Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9 % + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20% LoZ capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution: 6.000 A / 0.001
A Range/Resolution: 10.00 A / 0.01
A Accuracy: 1.5 % + 3 20 A continuous overload for 30 seconds max DC amps
Range/Resolution: 6.000 A / 0.001
A Range/Resolution: 10.00 A / 0.01
A Accuracy: 1.0 % + 3 20 A continuous overload for 30 seconds max Hz (V or A input) 2
Range/Resolution: 99.99 Hz / 0.01
Hz Range/Resolution: 999.99 Hz / 0.1
Hz Range/Resolution: 9.999 Hz / 0.001
Hz Range/Resolution: 50.00 Hz / 0.01
Hz Accuracy: 0.1 % + 2

storage_Type No
Manufacturer Part No FLUKE 117C
Manufacturer No
Datasheet No

Use spaces to separate tags. Use single quotes (') for phrases.

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Products Questions:

There are no product questions yet.

Please login in to your account to place a question

Back to top