Specifications:
Electrical Specifications-
DC Voltage:-
Range- 0.1 mV to 1000 V
Accuracy- ±(0.05% + 1)
Maximum resolution- 0.1 mV
AC Voltage:-
Range- 0.1 mV to 1000 V
Accuracy- ±(0.7% + 4) true-rms
AC bandwidth- 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution- 0.1 mV
DC Current:-
Range- 0.1 μA to 10 A (20 A for 30 seconds maximum)
Amps accuracy- ±(0.2% + 2)
Maximum resolution- 0.1 µA
AC Current:-
Range- 0.1 μA to 10 A (20 A for 30 seconds maximum)
Amps accuracy- ±(1.0% + 2) true-rms
Maximum resolution- 0.1 µA
Resistance:-
Range- 0.1 Ω to 50 MΩ
Accuracy- ±(0.2% + 1)
Maximum resolution- 0.1 Ω
Capacitance:-
Range- 0.01 nF to 9999 μF
Accuracy- ±(1% + 2)
Maximum resolution- 0.01 nF
Frequency:-
Range- 0.5 Hz to 199.99 kHz
Accuracy- ±(0.005% + 1)
Maximum resolution- 0.01 Hz
Duty cycle:-
Maximum duty cycle- 99.9%
Accuracy- ±(0.2% per kHz + 0.1%)
Maximum resolution- 0.1%
Conductance:-
Maximum conductance- 60.00 nS
Accuracy- ±(1.0% + 10)
Maximum resolution- 0.01 nS
Diode test:-
Range- 2 V
Resolution- 0.001V
Accuracy- ±(1% + 1)
Display:-
Digital- 6000 counts updates 4/second, 19,999 counts in high–resolution mode
Analog bar graph- 32 segments, updates 40/second
Backlight- Two level
IP rating- IEC 60529: IP67
Size- 6.0 x 10.1 x 21.5 cm (with holster)
Weight- 698.5 g (with holster)
| storage_Type | No |
|---|---|
| Manufacturer Part No | FLUKE-87V-MAX/E2 |
| Manufacturer | No |
| Datasheet | No |
Products Questions:
There are no product questions yet.